Datacap Logo

Ingenico iSC Touch 480 – Static IP

What do I need to set-up the isc Touch 480?

  • Ingenico iSC Touch 480
  • iSC Touch 480 power supply
  • iSC Touch 480 Ethernet cable
  • TranCloud Unit
  • TranCloud power supply
  • IP Address for wireless Network (What’s this?)
  • Gateway Address for wireless Network (What’s this?)

1.)  Connect iSC Touch 480 Ethernet cable to the back of the Ingenico iSC TOuch 480 and into one of the LAN ports on your internet router.

 Connecting the Ethernet cable

 Note:  The make/model of your internet router and the Ethernet cables connected to it will look different than the one used to make this guide.

Note:  The make/model of your internet router and the Ethernet cables connected to it will look different than the one used to make this guide.

 

2.)  Connect iSC Touch 480 power supply to 120V power outlet and to the back of the iSC Touch 480 Ethernet cable.

 Power Cable

Note: iSC480 will turn on once it’s connected to power.

 

3.)  Once the iSC Touch 480 loads the “splash” screen, quickly press 2-6-3-4, enter key, followed by the “F” key.

 iSC250/iSC480 splash screen
iSC250/iSC480 splash screen

4.)  Use the included stylus to scroll down and select “TDA”.  

 TDA

 

5.)  For the remaining steps, you’ll need to use the F/# keys to scroll up and down. Select “Configuration” and press the enter key, “Communication” and press the enter key, and “Select Comm. Type” and press the enter key.  Choose “Ethernet” and press the green enter key.  Press the red cancel key to return to the previous screen.

 Plus/Minus Keys

 Configuration

 Select Comm Type

 Communication

 Ethernet

 

6.)  Scroll down to “Ethernet settings” and press the enter key.  Scroll down to “IP Address” and press the enter key to enter your wireless network’s IP Address. Press enter. scroll to Select “Gateway” and press the enter key to enter your Gateway Address. Be sure to press the enter key after changing any settings.  

 Ethernet Settings for iSC250/iSC480
Ethernet Settings for iSC250/iSC480
 Ethernet Settings Options
Ethernet Settings Options
 Enter IP Address
Enter IP Address

Scroll through the “Ethernet settings” options to confirm the following settings:

  • “Connection Method” is set to “Server”
  • “DHCP” is set to “Static”
  • “IP Port” is set to “12000”
  • “-SSL” is set to “No” 

 

7.)  Press the red cancel key three times.  Press the “1” key (Yes) at the “Save and Reboot” screen. The iSC Touch 480 will then reboot.

 The iSC250 will reboot with the settings for Ethernet connection after you select

 

8.)  Connect TranCloud unit to 120V power outlet using included TranCloud power supply.